Oil-free air compressor is an efficient compressed air equipment, and its adjustment process mainly includes the following steps.
Step 1: Check the device and environment
Before adjusting the oil-free air compressor, we must first check whether the equipment and the environment meet the requirements. Check whether the equipment is intact and the components are in normal operation; Check whether the environment is well ventilated, the temperature is appropriate, and the noise is acceptable.
Step two: Check the air filter
The air filter of oil-free air compressor is an important part of ensuring the quality of compressed air. Check whether the filter is clean and whether the filter element needs to be replaced. If it is found that the filter element has exceeded its service life, it should be replaced in time.
Three steps: Adjust your stress
Adjusting the pressure of oil-free air compressor is the key to ensure its normal operation. First determine the required pressure range, and then use the pressure gauge to adjust the pressure. According to actual needs, gradually adjust the pressure switch or regulating valve until the required pressure reaches the set value.
Four steps: Clean the compressor
The compressor of the oil-free air compressor also needs regular cleaning and maintenance. First, the compressed air is used to purge the dust and dirt on the surface of the compressor; Then, use an appropriate cleaner to clean the sliding parts and seals inside the compressor. After cleaning, wipe the compressor clean with a clean cloth.
Five steps: Check the cooling system
The cooling system of oil-free air compressor is the key to ensure the normal operation of equipment. Check whether the cooling fan and radiator are clean and blocked. If necessary, compressed air or brushes can be used to clean the cooling system and ensure its normal operation.
Step six: Check the lubrication system
Although the oil-free air compressor does not require an external lubricant, it still has an internal lubrication system that needs to be checked. Check whether the amount of lubricating oil is sufficient and whether the lubricating oil needs to be replaced. If the amount of lubricating oil is insufficient or the quality is reduced, the lubricating oil should be supplemented or replaced in time.
Seven steps: Check the drainage system
The drainage system of the oil-free air compressor is mainly used to remove moisture and dirt from the compressed air. Check whether the drainage valve works properly and the drainpipe is unblocked. If the drainage valve is abnormal or the drainage pipe is blocked, clean or replace it in time.
Eight steps: Check the stability protection device
The stability protection device of oil-free air compressor is an important part of protecting the operator and equipment. Check all kinds of switches, overload protection devices and emergency shutdown devices are working properly, if necessary, should be repaired or replaced in time.
Nine steps: Trial run and adjustment
After completing the above steps, trial operation and adjustment can be carried out. Turn on the power supply of the oil-free air compressor and observe its operating status and pressure changes. According to the actual situation, timely adjust the pressure switch or regulating valve to achieve a better operating state.
Through the adjustment of the above steps, the oil-free air compressor can maintain efficient and reliable work to provide users with a stable supply of compressed air. At the same time, regular adjustment and maintenance can also extend the service life of the equipment, reduce the failure rate, reduce downtime, and improve production efficiency.