Oil-free air compressor is a type of air compressor that does not require the use of lubricating oil for lubrication and cooling, so it can reduce pollution to the environment during use. In order to ensure the normal operation of the oil-free air compressor, debugging is very important. The following is the detailed method of commissioning oil-free air compressors:

1. Installation and connection:

First of all, it is necessary to install the oil-free air compressor on a stable basis to ensure that the base of the air compressor is stable. Next, connect the inlet and exhaust pipes of the air compressor to the corresponding pipes. Ensure that the connection port is well sealed to avoid gas leakage.

2. Electrical connection:

Connect the power cord to the power outlet of the oil-free air compressor to ensure that the electrical connection is correct and reliable. Check whether the power cord is worn or cracked to prevent the wire from being exposed.

3. Gas pipeline inspection:

Check that the gas line is clear and secure any blocked or leaking areas. Pay special attention to check whether the gas filter and exhaust valve are working properly.

4. Preparation before operation:

Open the control switch on the oil-free air compressor and set the pressure regulating valve to the required working pressure. Then, open the power switch of the air compressor to confirm the normal power supply.

5. Air compressor start:

64b5b8012fe92.jpg

Press the start button of the oil-free air compressor and observe whether the air compressor starts normally. During the startup process, pay attention to the change of the pressure gauge to ensure that the pressure gradually increases to the set working pressure.

6. Air compressor operation monitoring:

During the operation of the air compressor, it is necessary to monitor the running status of each component. Pay attention to the noise, vibration and temperature of the air compressor to ensure that it is within the normal range. At the same time, observe whether the indicator of the pressure gauge is stable within the set working pressure range.

7. Troubleshooting:

If the air compressor is found to have abnormal conditions during commissioning, such as excessive noise, serious vibration, or abnormal indicator of the pressure gauge, troubleshoot the fault. Check the various parts of the air compressor, find the possible causes of failure, and take appropriate measures to repair.

8. Run tests:

When the air compressor is operating normally and normally, some running tests are carried out to verify its performance. For example, the performance of air compressors under different loads can be tested to observe their pressure stability and response speed.

9. Shutdown and maintenance:

After the commissioning is completed, first turn off the power switch of the oil-free air compressor, then close the gas intake valve, and finally set the pressure regulator to a lower pressure. Perform necessary cleaning and maintenance work, including cleaning the filter, removing water, etc.

In the process of commissioning the oil-free air compressor, it is necessary to pay attention to the stability problem. Use specialized personal protective equipment to ensure responsibility for the safety and stability of yourself and others. In addition, if you encounter a fault or problem that cannot be solved, you should seek help and advice from advanced people in time.

The above is a detailed introduction to the debugging method of oil-free air compressor, and I hope it can help you.